A Northeast Acid Mine Drainage (AMD) treatment facility was using calcium hydroxide (lime) to precipitate iron from the mine pool water. The iron in the water stream is in soluble form known as ferrous iron (Fe2). Lime was used to...
Read More
A refinery in the Northeast was looking at options to dispose of 10,000 bbls of a high strength, high pH caustic wastewater that had been stored in one of its tanks. The wastewater had very high phenol levels (14,000 mg/L), which did not allow for processing through the activated sludge...
Read More
ABSTRACT
The results of a full-scale trial initiated in May 2006 by the Manatee County Southwest Water Reclamation Facility are presented, and the impacts of peroxide regeneration of spent iron salts on the removal of hydrogen sulfide (H2S) from anaerobic digesters at the SWWRF are examined. Treatment with hydrogen peroxide...
Read More
ABSTRACT
The paper will present results of a trial initiated in February 2004 by the San Antonio Water System (SAWS) to quantify the impacts of hydrogen peroxide injection prior to dissolved air flotation thickening of wastewater sludges. Since February 2000, the San Antonio Water System has successfully used iron salts...
Read More
Project Scope
A Midwest wastewater treatment plant was struggling with problematic hydrogen sulfide (H2S) levels at two points within their facility arising from biosolids processing. The factors driving the need for H2S control included worker safety, corrosion of electronics and concrete, implied regulatory limits and biosolids odor control. Along with...
Read More
Project Scope
A field demonstration was initiated in February 2014 by the Suffolk County Department of Public Works (SCDPW) to quantify the impacts of Peroxide Regenerated Iron-Technology (PRI-TECH®) as a more economic approach in maintaining biosolids odor control in the solids handling phase at the Bergen Point Wastewater Treatment Plant...
Read More
Project Scope
In upstate New York, a wastewater treatment facility historically utilized potassium permanganate to control odors at two locations in their biosolids processing operations. The first location was into the waste activated sludge (WAS) fed to a gravity belt thickener. The second location was into a mixed stream of...
Read More
ABSTRACT
Historically, ferrous chloride (FeCl2) injection has been utilized to successfully control odors and corrosion within the sanitary sewer collection system of Fargo, North Dakota. However, increased odor complaints prompted an evaluation of the odor conditions present in the sanitary sewer system. Study results indicated that the current FeCl2...
Read More
ABSTRACT
This paper describes the evolving odor control program of the City of Wichita, Kansas from 2008 to 2015. In 2010, the City reduced odor control technology expenditure due to a reduction of revenues. The odors increased resulting in an upswing in citizen complaints as well as more corrosion...
Read More
5640 Cox Rd.
Glen Allen, VA 23060
Toll-free (800) 851-8527
Phone (804) 404-7696
3020 Gore Road
London, Ontario N5V 4T7
Toll-free (800) 851-8527
Phone (804) 404-7696