Summary
This paper will present results of an odor control field study initiated in July 2008 by Lexington-Fayette Urban County Government (LFUCG) to quantify the impacts of iron and peroxide injection in the collection system on liquid and gaseous sulfide levels as well as the secondary benefit of phosphorus removal...
Read More
ABSTRACT
Historically the technology to continuously monitor “odors” or odor units in real time has not been available. Since October 2009, the Hampton Roads Sanitation District (HRSD) has been successfully demonstrating new technology that is performing real time odor monitoring of the odors from the uncovered portion of the...
Read More
ABSTRACT
Historically, ferrous chloride (FeCl2) injection has been utilized to successfully control odors and corrosion within the sanitary sewer collection system of Fargo, North Dakota. However, increased odor complaints prompted an evaluation of the odor conditions present in the sanitary sewer system. Study results indicated that the current FeCl2...
Read More
Abstract
The transition from splash fill and ACB fill to cellular plastic “high efficiency” film fill in cooling towers has reduced capital and operating costs. However, the generally tight and tortuous path that provides exceptional contact between air and water in these fills also makes them highly prone to fouling....
Read More
ABSTRACT
In 2008, the Green Bay (Wisconsin) Metropolitan Sewerage District acquired the De Pere Wastewater Treatment Facility and interceptors from the City of De Pere. Two of those interceptors received wastewater from paper mills exhibiting high biochemical oxygen demand and high temperatures. Mill wastewater contributed 80 percent of the total...
Read More
Abstract
Free Nitrous Acid (FNA) is the active agent underlying a new biofilm removal technology (“Cloevis”) for controlling sulfide production in wastewater force mains. The technology was developed at the University of Queensland and, after initial field testing in Australia, commercial field tests in the U.S. began in late...
Read More
Hydrogen Sulfide Control in Bio-Solids Processing
Hydrogen Peroxide – The Cedar Rapids Experience
The City of Cedar Rapids Water Pollution Control Facility (WPCF) treats an average of 42 MGD of mixed industrial and domestic wastewater. Due to the large percentage of industrial wastewater contribution (e.g. paper mills, corn processors, agricultural...
Read More
Introduction
USP-OC31 is a chlorite-based oxidant blend that is designed to efficiently and rapidly oxidize hydrogen sulfide and organic odors in wastewater collection systems, treatment plants (headworks, thickeners, dewatering operations) and industrial wastewaters. USP-OC31 is environmentally friendly and does not form chlorinated by-products, with the end-product being table salt (sodium...
Read More
Introduction
Sulfide odor control within sanitary sewers has been practiced for over 50 years, yet only recently have substantive advances been made. Where once the choice of chemical treatment was either chlorine or iron salts, safer and more environmentally benign technologies based on hydrogen peroxide, nitrates and/or magnesium hydroxide have...
Read More
5640 Cox Rd.
Glen Allen, VA 23060
Toll-free (800) 851-8527
Phone (804) 404-7696
3020 Gore Road
London, Ontario N5V 4T7
Toll-free (800) 851-8527
Phone (804) 404-7696
"*" indicates required fields